Fri. Nov 8th, 2024

A3 Business News

A3 News | All business news all over the world.

Radar level transmitter manufacturer with kaidi86.com

4 min read

Top Radar level transmitter supplier factory: In daily life and industrial production and operation, often need to understand the liquid level in the container. Part of the situation is due to the tank is too large, people are not convenient to enter and tanks and other container materials are not permeable and other factors, this time the need for relevant instrumentation to help, then you know, liquid level measurement are where the instrumentation? It is reported that the instrumentation to measure the liquid level is called liquid level meter. Liquid level meter for the level of a kind of instrumentation. Types of liquid level meters are tuning fork vibration type, magnetic floating type, pressure type, ultrasonic, sonar wave, magnetic flap, radar and so on. Discover extra information at radar level transmitter suppliers.

Radar level measurement represents a shift in the field of instrumentation. This state-of-the-art technology utilizes radar waves to determine levels of liquids or solids, in vessels. Unlike methods that require contact radar operates non invasively by emitting microwaves and carefully analyzing the reflected signals. The key radar level measurement principle here is time of flight measurement- accurately measuring the time it takes for a radar pulse to travel from a transmitter, bounce off the surface of the material and return to a receiver. This temporal data is then converted into an accurate level reading.

If the radar level meter is unreasonably selected, the interference echo cannot be handled well, and the reliability of the instrument will be reduced. Therefore, the following factors should be considered when selecting a radar level meter: Conductivity and dielectric constant of the measured medium. The measured medium is a conductive liquid or a liquid with a dielectric constant above 4. Generally, a common radar is selected. Liquids with small dielectric constants (dielectric constants below 2) and some conductive solids often use precision radars or guided wave radars due to the large amount of interference echoes.

The electromagnetic wave emitted during measurement can pass through the vacuum, no transmission medium is required, and the anti-interference ability is strong, and it is not affected by temperature, wind, water vapor, water mist, rain, etc. It can be used for liquid level measurement of almost all liquids, and can be continuously measured on-line unattended. Large measurement range, high precision, mature technology and stable performance.

Level Measurement Solutions for Deaerators: With proper level control and instrumentation, every part of the steam generation cycle can be managed for optimal efficiency. Deaerator Functions: The deaerator serves as an “open” type heat exchanger with its primary function being the removal of oxygen and other corrosive gases from the boiler feedwater. This is accomplished using steam, which can give up about 970 Btu per pound, to support the deaeration process as well as preheat boiler feedwater.

In addition, some silos in cement plants are very high, such as homogenizing silos of 50cm. It takes time and energy to board high silos to debug radar, so it is recommended to choose HART handheld operators that can be debugged remotely in the central control room. In the central control room, the range and other basic parameters can be set, and the radar echo waveform can be observed, and the waveform can be used for remote diagnosis and debugging, greatly reducing the on-site work intensity of the staff, to avoid the risk of climbing operation. The smart radar level gauge commonly used at present also has a function similar to “driving recorder”, that is, when the material surface mutation occurs on the scene, it can capture the radar echo waveform at that time, which is very useful for debugging the silo under complex conditions.

As one of the most professional magnetic level indicators manufacturers in China,Guangdong Kaidi Energy Technology Co., Ltd. provides customized solutions for a range of industrial automation process applications,such as mechanical float level indicator.We specialized in radar level gauge, fork type level switch,etc. These were implemented successfully, and KAIDI magnetic level gauge manufacturers products,such as radar level meter, magnetic level indicators, can be used in many different industries such as food & beverage, water, energy, pharmaceutical etc. See more info on https://www.kaidi86.com/. Suitable for chemical industry, petroleum industry, metallurgical industry, water conservancy and electronic industry, etc.

Thermal interference. During the operation of the thermal power plant, its thermal equipment will generate a lot of heat, causing changes in the surrounding instruments and ambient temperature. This is what we call thermal interference. These disturbances can affect the components of the magnetrol radar level gauge and further create problems such as inaccurate measurements. Light interference, light interference mainly exists in semiconductor components. Many components used to control instruments are made of semiconductor materials whose conductivity changes under the influence of light. This will affect the normal use of the radar level gauge.

Working principle: Working principle of radar level gauge: UHF electromagnetic waves are transmitted to the liquid level of the container under test through the cable or antenna. When the electromagnetic wave touches the liquid level and is reflected back, the instrument detects the time difference between the initial wave and the echo, thereby calculating the liquid level height. Select guided wave radar or airborne radar according to the dielectric constant and measurement length of the measured medium.

The whole process measurement is rain proof, corrosion proof, high temperature, high pressure, leakage proof, no blind area, eye-catching display, intuitive reading, and a wide measurement range, suitable for all kinds of towers, tanks, tanks, spherical vessels and boilers and other equipment continuous measurement of liquid level. Optional liquid level alarm switch, can realize the upper and lower limit of liquid level alarm and control.

Copyright © All rights reserved. | Newsphere by AF themes.