Wed. May 15th, 2024

A3 Business News

A3 News | All business news all over the world.

Ftir analysis company by Microvisionlabs.com in 2021

3 min read

Eds analysis company in the USA right now? Analysis and Results: The submitted bottle was examined for signs of interior distress, and the water from the bottle was removed and maintained. Some of the suspended particulate was filtered and examined non-destructively by light microscopy first, to characterize the material. A low magnification stereo microscope image of the filtered white particulate is shown in the image above. From this image, biological tissues were ruled out, and the material was observed to be crystalline. Polarized light microscopy (PLM) was used to analyze the sample next. From this examination, the material showed birefringence as shown in the PLM image on the right. The PLM Image Stereo Microscope image suspect material showed optical properties and morphology dissimilar to common carbonates and sulfates. It was determined to be a birefringent crystalline material, but it could not be identified using only PLM methods. Therefore, analysis using scanning electron microscopy with energy dispersive x-ray spectroscopy (SEM-EDS) would have to be performed to obtain further information about the suspect material.

The diameter, perimeter, shape and aggregation patterning of particles are often of interest with manufactured or naturally occurring materials. Our PSA method is useful to measure and document the morphology and distribution of a sample. Whether you have particles, pores or film coatings, we can accommodate your project needs. Scanning Electron Microscopy (SEM)

Do you do any animal testing? No. Do you analyze any tissue samples or blood samples? No. We do not do any blood analyses and we are not set up to prepare tissue samples. What are some of the cool samples you have looked at under the scanning electron microscope? We have seen 10,000 year old Wolly Mammoth hair, meteorites, an artificial heart valve, civil war bullets, insulin pumps, rare colonial coins, a kidney stone, and a few things we can’t talk about. But some of the more mundane samples, like wood or salt crystals, have proven to be extremely interesting subjects to image. See a few more details on top rated microscopy laboratory. ?We partner with companies in all phases of product development and sales, including R&D, manufacturing, QC, advertising and failure analysis. Our laboratory offers a highly-trained and experienced staff utilizing a powerful set of analytical tools (SEM with EDS and backscatter detectors, Bruker X-Flash elemental mapping, X-Ray imaging, Micro-FTIR spectroscopy, Micro-XRF, light microscopy, cross sectioning/precision polishing and microhardness testing).

A device manufacturer had a product that involved a few different boards with varying components. There were circumstances that caused the need for a change in manufacturers of one of the boards. Due to this change, the device production at this facility would be shut down until the boards from this new vendor were validated. The Quality Control department required that an inspection of the solder joints of some of the components on the board be analyzed in order to determine whether this new board manufacturer met their specifications. If the desired specifications were met and no issues were found during the inspection of the joints then production of the devices could resume.

Dust samples were analyzed using polarized light microscopy (PLM) to provide percentages of the particle types present in the samples. MVL was able to determine that there was significant loading of glass fibers in the dust samples with the likely source being contractor’s work in the attic which involved disturbing the fiberglass insulation. The image on the right shows a few distinct glass fibers with a binder material adhered to them, consistent with fiberglass insulation. See additional info on https://microvisionlabs.com/.

Copyright © All rights reserved. | Newsphere by AF themes.